Valves / Hygienic / Aseptic / Speciality Process Valves
Double-Seat Mixproof Valve
Mixproof valves offer reliable separation of two media such as product and CIP cleaning allowing a reduction in the number of single seat valves required and optimizing plant efficiency.





The INNOVA type mix proof valve is a pneumatic shutoff double seat valve for hygienic applications. The leakage chamber, under atmospheric pressure, situated between the two seats ensures a safe interface between the two liquids, one of which is usually a CIP solution (cleaning agent). The leakage chamber can be cleaned by independent lifting of the seats during the CIP cleaning of the line.
Hygienic design according to 3A
No leakage during the opening/closing of the valve
Balanced lower seat
Single-acting pneumatic actuator
Easy assembly/disassembly of internal parts by loosening a clamp fastener
Open lantern allows visual inspection of shaft sealing
360º adjustable body
Parts in contact with the product AISI 316L (1.4404)
Other stainless steel parts AISI 304 (1.4301)
Gasket EPDM (according to FDA and EC 1935/2004)
Surface finish: Internal Bright Polish Ra ≤ 0,8 μm / External Matt
Available sizes - ASME BPE OD 1.5" - OD 4"
Connections Weld or triclamp
Double-acting pneumatic actuator
Gaskets: FPM, HNBR
Other connection types
Control unit: C-TOP, C-TOP+ and C-TOP S
External position sensors
Surface finish: Ra ≤ 0,5 μm
Meet your clean and aseptic
process specialist
Discover our custom-made solutions and modular sanitary equipment. We join forces with our expert partners to develop, design and integrate proven solutions.